The Daikin FDYAN100AV1 is a 10.0kW single-phase inverter ducted system with 12.5kW of heating output — a common specification for larger family homes across Singleton and the Hunter Valley.
Coalfields Climate Control designs and installs ducted systems locally, starting with a heat-load calculation rather than a rule of thumb.
Overview of Daikin 10.0kW Inverter Ducted Reverse Cycle System (FDYAN100AV1)
▾The FDYAN100AV1 pairs with the RZA100CV1 outdoor unit on 240V single-phase supply. Rated capacity is 10.0kW cooling and 12.5kW heating, modulating from 3.2kW to 11.2kW in cooling.
Airflow rises to 680 l/s nominal and 800 l/s maximum, which is the practical reason this size suits larger homes — it is not just capacity but the ability to move air far enough down long duct runs to reach the back bedrooms.
The indoor unit remains on the shallow 300 x 1210 x 900 mm chassis but weighs 45kg. The outdoor unit is 990 x 940 x 320 mm at 69kg, the same as the 8.5kW model.
Refrigerant is R32, on a 50m maximum pipe run. Daikin requires R32 ducted indoor units to be installed in the ceiling space, not under floor.
– 12.5kW heating output for strong winter performance across a large home
– 680 l/s nominal airflow for long duct runs to distant rooms
– Still on the shallow 300mm indoor chassis
– Runs on standard 240V single-phase supply
– Zoning compatible for room-by-room control
– R32 refrigerant
– 50m maximum pipe run
– 5-year parts and labour warranty when professionally installed
Is the Daikin 10.0kW Inverter Ducted Reverse Cycle System (FDYAN100AV1) right for your home?
▾– Larger family homes, roughly 120 to 200 m2 of conditioned floor area
– Four and five-bedroom homes with rooms distant from the plant location
– Two-storey homes where a single system serves both levels through zoning
– Homes with moderate to high heat load from glazing or orientation
– Properties where the previous ducted system could not reach the far bedrooms
If your home is larger than about 200 m2, or has a difficult layout, look at the 12.5kW or 14.0kW rather than pushing this one to its limit.
Performance & Efficiency
▾Capacity range 3.2-11.2kW cooling, 3.5-14.0kW heating. TCSPF (residential) 4.28/3.88/3.97 and HSPF 3.85/3.48/3.04 (hot/average/cold) under the GEMS 2019 Determination. Airflow 680/800 l/s nominal/max. Figures measured to AS/NZS 3823.1.2.
Noise Levels
▾Indoor sound level at high fan, measured 1.5m from the unit. Outdoor sound pressure at high fan, measured 1m from the unit. EPA sound power level 71 dBA. Ducted indoor units sit in the ceiling space, so in-room noise depends heavily on duct design and grille selection.
Power & Installation
▾Refrigerant & Environment
▾R32 has a substantially lower global warming potential than R410A. Daikin requires R32 ducted indoor units to be installed in the ceiling space, not under floor.
Dimensions & Weight
▾Warranty
▾Model Details
▾Features
▾Energy Efficiency & Performance
▾The FDYAN100AV1 is rated at 3.23 EER cooling and 3.73 COP heating. Seasonal figures under GEMS 2019 are a TCSPF of 4.28 / 3.88 / 3.97 and HSPF of 3.85 / 3.48 / 3.04 across hot, average and cold zones.
Rated input is 3.10kW cooling and 3.35kW heating. On a single-phase supply that is a serious continuous load, and switchboard capacity genuinely needs checking — this is one of the checks that catches people out when a system is quoted without a site visit.
The TCSPF of 3.88 in the average zone is essentially identical to the 8.5kW model, so stepping up in capacity here does not cost you seasonal efficiency the way it does on wall-mounted units. That makes correct sizing less financially punishing on ducted, but it does not make oversizing free — a larger system costs more to buy and cycles more at light load.
Installation Notes for the Daikin 10.0kW Inverter Ducted Reverse Cycle System (FDYAN100AV1)
▾This system pairs the FDYAN100AV1 indoor unit with the RZA100CV1 outdoor unit, on a 240V single-phase supply, with a maximum pipe run of 50m.
A ducted system is a building job as much as an equipment job. Before quoting, Coalfields Climate Control assesses ceiling space and access, plans the zone layout and duct runs, calculates the heat load room by room, checks the electrical supply, and confirms where the outdoor unit can sit without creating a noise problem at a boundary.
What supply and install through us covers:
– Manufacturer-approved installation by qualified technicians, so the warranty is not compromised by a non-compliant install
– A lifetime guarantee of workmanship on the installation itself
– A 10-day install guarantee on split system installations in Singleton
– Drop sheets laid before work starts, mess cleaned up afterwards, and a walkthrough of how to operate the system
The most common problem we are called out to fix is not a faulty unit — it is an installation issue: undersized selection, poor outdoor unit placement, or drainage that was never set up properly. Getting the supply and the install from one local team means one number to call if anything is not right.
To arrange a site assessment and quote, call 0422 493 102.
Warranty Information
▾Daikin provides a 5-year parts and labour warranty on ducted systems professionally installed in domestic premises in Australia.
That warranty depends on the installation being carried out correctly by a qualified installer, and on normal use and maintenance. A DIY or unlicensed install is the fastest way to void it — and handling refrigerant without a licence is an offence in Australia regardless of the warranty position.
Coalfields Climate Control installs to manufacturer specification and is manufacturer-approved for full warranty servicing across all major brands, so ongoing servicing can be handled locally rather than through a metropolitan agent. Our own workmanship carries a lifetime guarantee on top of the product warranty.
Warranty coverage depends on correct installation, normal use, maintenance requirements and the manufacturer current warranty terms.
Frequently Asked Questions
▾What size home does the FDYAN100AV1 suit?
Roughly 120 to 200 m2 of conditioned floor area. Floor area is only a rough guide though -- ceiling height, insulation, glazing and orientation change the answer significantly. We do a room-by-room heat-load calculation on site before quoting a ducted system.
Do I need a three-phase power supply?
It runs on a standard 240V single-phase supply, so most homes will not need a supply upgrade. We still check switchboard and circuit capacity during the assessment, because a system this size adds a substantial load alongside everything else in the house.
Will the indoor unit fit in my roof space?
The indoor unit is 300mm high and 1210mm long, and it has to be lifted into position as well as fitted. Ceiling space and access route are among the first things we check on site -- it is far better to find a problem at assessment stage than on installation day.
What refrigerant does it use?
R32, which has a lower global warming potential than the older R410A and costs less to top up if the system ever needs a regas. Daikin requires R32 ducted indoor units to be installed in the ceiling space, not under floor.
How much does a ducted system cost to install in Singleton?
Ducted pricing depends on the number of zones, duct runs, ceiling access, electrical work and where the outdoor unit can go -- far more variable than a split system. We quote after a full site assessment and heat-load calculation. Call 0422 493 102 to arrange one.
Does zoning actually save money?
Yes, and it is the single biggest lever on running cost. Conditioning three rooms instead of seven cuts consumption roughly proportionally. Getting the zone plan right at design stage matters more to your bills than small differences in equipment efficiency ratings.